Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Intervalo de año de publicación
1.
Clin Oral Investig ; 26(1): 957-967, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34286399

RESUMEN

OBJECTIVES: The aim of this study was to investigate the mechanical, chemical, optical, and adhesive properties of BisGMA-free experimental resin composites containing Exothane-24-an elastomeric urethane monomer-and different co-initiators. MATERIALS AND METHODS: A blend of urethane dimethacrylate (UDMA), extended dimethacrylate urethane (PEG 400), triethylene glycol dimethacrylate (TEGDMA), and camphorquinone was prepared. Two different co-initiators-dimethyl aminoethyl methacrylate (DMAEMA) or 4-N alcohol, N-dimethylamine phenylethyl (DMPOH)-were added to the blend. Exothane-24 monomer was added to the blend for each co-initiator and four groups were established as follows: DMAEMA; DMAEMA + Exothane; DMPOH; and DMPOH + Exothane. Specimens were photo-activated using a multi-wave LED light-curing unit (VALO; 954 mW/cm2 of irradiance). Mechanical (ultimate tensile strength, flexural strength, flexural modulus and hardness), chemical (degree of conversion, hardness reduction, water sorption and solubility), optical (color change), and adhesive (microtensile bond strength) properties were analyzed. Data were submitted to two-way ANOVA and Tukey's test (α = 0.05). RESULTS: The resin composite containing DMPOH and Exothane-24 showed similar or superior performance to those of the other experimental composites for mechanical and chemical properties, except for flexural strength. It also showed less color change and greater micro-tensile bond strength. CONCLUSIONS: Among the combinations tested, the BisGMA-free resin composite containing Exothane-24 combined with the DMPOH co-initiator showed the best mechanical, chemical, optical, and adhesive properties. Clinical relevance Exothane-24 monomer and DMPOH co-initiator could be useful in the formulation of BisGMA-free resin composites in order to minimize exposure to BPA.


Asunto(s)
Resinas Compuestas , Metacrilatos , Bisfenol A Glicidil Metacrilato , Ensayo de Materiales , Polietilenglicoles , Polimerizacion , Ácidos Polimetacrílicos , Resistencia a la Tracción
2.
Saudi Dent J ; 33(8): 1111-1118, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34938056

RESUMEN

AIMS: The aim of this study was to develop and characterize a temporary restorative material based on a zinc oxide matrix containing niobophosphate bioactive glass (NbG) for the caries-affected dentin treatment. MATERIAL AND METHODS: NbG was added to a ZnO2 matrix in different concentrations (wt%). EDS-SEM, ATR-FTIR and XRD analyses were performed to characterize the cement. Calcium release was evaluated in TRIS solution after 1, 7 and 14 days by colorimetric method (A650). Compressive strengths and setting times were performed to analyze mechanical properties. RESULTS: EDS spectra confirmed the presence of Ca, P and Nb in the groups containing NbG. EDS mapping exhibit the ZnO2 homogeneous distribution, and NbG immersed in this matrix. Peaks suggesting interaction between matrix and NbG were not detected in Ftir spectra. Calcium releasing showed to be time-dependent for experimental groups containing 10, 20, 30 and 40%. The NbG incorporation progressively increased the compressive strength values in the experimental groups. NbG incorporation seemed to influence the ZnO2 matrix early setting reaction. No statistical difference was observed in the final setting time. CONCLUSION: The addition of NbG particles into zinc oxide matrix could work as a mechanical reinforcement. It is suggested that the calcium released by the cement containing at least 10% NbG could induce apatite formation.

3.
Probiotics Antimicrob Proteins ; 13(6): 1808-1819, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34402021

RESUMEN

This study evaluated the cytocompatibility and antimicrobial/antibiofilm effects of epigallocatechin-3-gallate (EGCG) associated with peptide LL-37 and its analogue KR-12-a5 against oral pathogens. The effect of the compounds on metabolism of fibroblasts was evaluated by methyltetrazolium assays. Antimicrobial activity of the compounds was evaluated on Streptococcus mutans, Enterococcus faecalis, Actinomyces israelii, and Fusobacterium nucleatum under planktonic conditions, on single- and dual-species biofilms and E. faecalis biofilms in dentinal tubules and analyzed by bacterial counts and confocal microscopy. Data were statistically analyzed considering p < 0.05. EGCG and peptide combinations were not toxic to fibroblasts. KR-12-a5 showed synergistic or addictive effects with EGCG and LL-37 against all bacteria tested. However, EGCG associated with KR-12-a5 demonstrated the highest bactericidal activity on all bacteria tested, at lower concentrations. In single-species biofilms, EGCG + KR-12-a5 eliminated S. mutans and A. israelii and reduced E. faecalis and F. nucleatum counts around 5 log CFU/mL. EGCG + KR-12-a5 reduced E. faecalis (-3.93 log CFU/mL) and eliminated S. mutans in dual-species biofilms. No growth of E. faecalis and significant reduction in A. israelii (-6.24 log CFU/mL) and F. nucleatum (-4.62 log CFU/mL) counts were detected in dual-species biofilms. The combination of EGCG and KR-12-a5 led to 88% of E. faecalis dead cells inside dentin tubules. The association of EGCG and KR-12-a5 was cytocompatible and promoted synergistic effect against biofilms of bacteria associated with endodontic infections.


Asunto(s)
Antiinfecciosos , Biopelículas/efectos de los fármacos , Catequina/análogos & derivados , Péptidos/farmacología , Actinomyces/efectos de los fármacos , Antiinfecciosos/farmacología , Catequina/farmacología , Enterococcus faecalis/efectos de los fármacos , Fusobacterium nucleatum/efectos de los fármacos , Streptococcus mutans/efectos de los fármacos
4.
Biofouling ; 37(6): 591-605, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34210215

RESUMEN

The objective of the study was to evaluate the cytotoxicity and effect of curcumin-cinnamaldehyde hybrids (CCHs) on the biofilm of oral pathogens. Of the 18 hybrids tested, nine had an inhibitory effect on at least one of the bacterial species tested, with minimal inhibitory and bactericidal concentrations ranging from 9 to 625 µg ml-1. CCH 7 promoted a potent inhibitory effect against all the bacterial species tested and better compatibility than chlorhexidine (CHX). CCH 7 also presented a similar or improved effect over that of CHX, causing a reduction in bacterial metabolism and viability in single and dual-species biofilms. CCH 7 reduced by 86% and 34% the viability of multispecies biofilms formed by collection and clinical strains. It can be concluded that CCH 7 was cytocompatible at the minimal inhibitory concentration, presented anti-biofilm action against oral pathogens, and could act as an antimicrobial agent for application in endodontics.


Asunto(s)
Curcumina , Acroleína/análogos & derivados , Antibacterianos/farmacología , Biopelículas , Clorhexidina/farmacología , Curcumina/farmacología , Pruebas de Sensibilidad Microbiana
5.
J Mech Behav Biomed Mater ; 119: 104529, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33910131

RESUMEN

To evaluate the effect of three adhesive systems applied under electric current on microtensile bond strength (µTBS) and degree of conversion (DC). Molar teeth were restored with the aid of three adhesive systems (Adper Single Bond 2-SB2; Clearfil SE Bond-CSE; and Single Bond Universal-SBU) under different electric current intensities (0 µA; 25 µA; and 50 µA). Composite resin blocks were built up in increments (2 mm) and sectioned into 1 × 1 mm beams. The µTBS was tested after 24 h and 1 y distilled water storages. Samples (n = 10) from 24 h to 1 y storages were immersed in a 50% ammoniacal silver nitrate solution and submitted to scanning electron microscopy. The silver nitrate in the hybrid layer was quantified (ImageJ software). The adhesive systems' dentinal infiltration was analyzed using confocal laser scanning microscopy. Fourier transform near infrared spectroscopy was used to measure the DC. The µTBS data were submitted to two-way ANOVA (time vs. electric current) and Bonferroni's test (α = 0.05). Quantitative nanoleakage data were submitted to two-way ANOVA (electric current vs. adhesive) and Bonferroni's test (α = 0.05). DC data were submitted to one-way ANOVA and Tukey's test (α = 0.05) for each adhesive system. The electric current statistically increased the µTBS for SB2 and CSE in 24 h storage, as well as for SB2, CSE and SBU in 1 y storage. No significant difference was observed between storage time for CSE and SBU. When compared to the control, electric currents (25 µA and 50 µA) showed significantly higher DC mean values for SB2 and SBU, and had no effect on CSE. The electric currents (25 µA and 50 µA) reduced the adhesive system's nanoleakage after 1-year storage, and improved the infiltration of SB2 and CSE. Both electric current intensities improved dentinal interface stability.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Adhesivos , Resinas Compuestas , Dentina , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Resistencia a la Tracción
6.
Clin Oral Investig ; 25(9): 5181-5188, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33558973

RESUMEN

OBJECTIVES: To evaluate the effect of electric current application on the resin composite-tooth bond strength and hybrid layer of three adhesive systems light-cured by two light-curing units (LCUs). MATERIALS AND METHODS: Human molar teeth were distributed into 12 groups (n=6). Three adhesive systems were used: two-step etch-and-rinse (SB2; Adper Single Bond 2, 3M ESPE); two-step self-etch (CSE; Clearfil SE Bond, Kuraray); and one-step self-etch (SBU; Single Bond Universal, 3M ESPE) applied with (50µA) and without (control; conventional application) electric current, and light-cured with different LCUs. Resin composite blocks (Filtek Z350XT, 3M ESPE) were produced and cut into sticks (~1mm2) for microtensile bond strength (µTBS). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-dentin, cohesive-resin, adhesive, or mixed. Specimens were prepared for scanning electron microscope observation. The hybrid layer analysis was carried out using a confocal laser scanning microscopy (n=2). Data were submitted to three-way ANOVA followed by Tukey's post hoc test (α=0.05). RESULTS: The electric current increased the µTBS for all adhesive systems light-cured with single-emission peak and multiple-emission peak LCUs. Both LCUs presented similar µTBS values. CSE applied under electric current showed the highest µTBS mean values. The adhesive failure pattern was more frequently observed in all groups. The electric current formed long resin tags for all adhesive systems. CONCLUSIONS: The adhesive systems applied under electric current increased the bond strength using single-emission peak and multiple-emission peak LCUs. CLINICAL RELEVANCE: Electric current at 50µA applied throughout the dentin is a safe mode and results in better impregnation of the adhesive systems.


Asunto(s)
Recubrimiento Dental Adhesivo , Resinas Compuestas , Dentina , Recubrimientos Dentinarios , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Resistencia a la Tracción
7.
J Adhes Dent ; 22(4): 393-398, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32666065

RESUMEN

PURPOSE: To assess the effect of the application of different electric currents on dentin bonding and resin infiltration of self-etching and etch-and-rinse adhesives. MATERIALS AND METHODS: Two hundred four sound third molars were selected and divided in groups according to the adhesive (self-etch [CSE, Clearfil SE Bond, Kuraray Noritake], universal [SBU, Single Bond Universal, 3M Oral Care], and etch-and-rinse [SB2, Adper Single Bond 2 (SB2), 3M Oral Care]) and electrical current used (0, 5, 10, 15, 20, 25, 30, and 35 µA). Light curing was performed for 10 s with an LED-curing unit at 1000 mW/cm2. Composite blocks were constructed of nanofilled composite in increments of 2 mm, which were light cured for 20 s. Specimens were sectioned into sticks with a cross-sectional area of ~1 mm2 and stored in distilled water at 37°C for 24 h. Microtensile bond strength (µTBS) testing (n = 8) was performed using a universal testing machine at a crosshead speed of 0.5 mm/min until failure. The bonding quality (n = 2) of adhesives applied with or without 35-µA electric current was evaluated using confocal laser scanning microscopy. Bond strengths were analyzed with two-way ANOVA and Tukey's test (α = 0.05). RESULTS: CSE presented the highest µTBS for all electrical currents tested. For CSE and SBU, electrical currents from 0-20 µA showed the lowest µTBS. Electrical currents from 0-10 and 20-25 µA yielded the lowest µTBS for SB2. CSE and SB2 applied under 35 µA showed a greater number of resin tags in dentin tubules. Fluorescein penetration into the hybrid layer was found for SBU applied without electric current. CONCLUSION: The application of adhesives using 35-µA electric current improved the bond strength and quality of the adhesive interface.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Adhesivos , Resinas Compuestas , Dentina , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción
8.
Braz Oral Res ; 33: e058, 2019 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-31432925

RESUMEN

Cementum is the mineralized tissue covering the tooth root that functions in tooth attachment and post-eruptive adjustment of tooth position. It has been reported to be highly similar to bone in several respects but remains poorly understood in terms of development and regeneration. Here, we investigate whether cementocytes, the residing cells in cellular cementum, have the potential to be protagonist in cementum homeostasis, responding to endocrine signals and directing local cementum metabolism. Cells from healthy erupted human teeth were isolated using sequential collagenase/EDTA digestions, and maintained in standard cell culture conditions. A cementocyte-like cell line was cloned (HCY-23, for human cementocyte clone 23), which presented a cementocyte compatible gene expression signature, including the expression of dentin matrix protein 1 ( DMP1 ), sclerostin ( SOST ), and E11/gp38/podoplanin ( E11 ). In contrast, these cells did not express the odontoblast/dentin marker dentin sialoprotein ( DSPP ). HCY-23 cells produced mineral-like nodules in vitro under differentiation conditions, and were highly responsive to inorganic phosphate (Pi). Within the limits of the present study, it can be concluded that cementocytes are phosphate-responsive cells, and have the potential do play a key role in periodontal homeostasis and regeneration.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Cemento Dental/citología , Proteínas Adaptadoras Transductoras de Señales , Adolescente , Adulto , Análisis de Varianza , Proteínas Morfogenéticas Óseas/análisis , Proteínas Morfogenéticas Óseas/genética , Línea Celular , Cemento Dental/metabolismo , Proteínas de la Matriz Extracelular/análisis , Proteínas de la Matriz Extracelular/genética , Femenino , Técnica del Anticuerpo Fluorescente , Expresión Génica , Marcadores Genéticos/genética , Humanos , Masculino , Glicoproteínas de Membrana/análisis , Glicoproteínas de Membrana/genética , Diente Molar/citología , Fosfatos/farmacología , Fosfoproteínas/análisis , Fosfoproteínas/genética , Sialoglicoproteínas/análisis , Sialoglicoproteínas/genética , Factores de Tiempo , Adulto Joven
9.
Braz Dent J ; 30(3): 272-278, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31166397

RESUMEN

The aim of this study was to use the isobornyl methacrylate (IBOMA) as a combining or substituent diluent monomer in the resin matrix of dental resin composites. Thus, the resin matrix was formulated with 60 wt% of BisGMA and 40 wt% of diluent monomers. TEGDMA as the only diluent monomer was used as control with 40 wt%, while total substitution of TEGDMA was done with 40 wt% of IBOMA. The combination of IBOMA and TEGDMA was done with 20 wt% of each monomer. To the resin matrix, 65 wt% of filler particles was added. Degree of conversion (DC) using FT-IR, flexural strength (FS), flexural modulus (FM), polymerization shrinkage by gap formation (GF), Knoop hardness (KH) and solvent degradation (SD) were evaluated. Data were analyzed using ANOVA and Tukey's test (α=0.05; b=0.2). The results showed that reducing or substituting TEGDMA using IBOMA did not affect the DC (0.085), FS (p=0.886) or FM (p=0.414). Also, when IBOMA was used, lower GF was found in comparison to the control containing only TEGDMA as the diluent monomer (p=0.032). However, even though all composites presented reduction in KH during the SD test, the combination of IBOMA and TEGDMA showed similar reduction in KHN in comparison to the control group (p=0.001), while the total substitution of TEGDMA with IBOMA decreased KHN after SD (p=0.041). Thus, the combination of IBOMA and TEGDMA seem to reduce SD and GF without affecting the properties of resin composites.


Asunto(s)
Resinas Compuestas , Metacrilatos , Bisfenol A Glicidil Metacrilato , Ensayo de Materiales , Polietilenglicoles , Polimerizacion , Ácidos Polimetacrílicos , Solventes , Espectroscopía Infrarroja por Transformada de Fourier
10.
Braz. oral res. (Online) ; 33: e058, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1019608

RESUMEN

Abstract Cementum is the mineralized tissue covering the tooth root that functions in tooth attachment and post-eruptive adjustment of tooth position. It has been reported to be highly similar to bone in several respects but remains poorly understood in terms of development and regeneration. Here, we investigate whether cementocytes, the residing cells in cellular cementum, have the potential to be protagonist in cementum homeostasis, responding to endocrine signals and directing local cementum metabolism. Cells from healthy erupted human teeth were isolated using sequential collagenase/EDTA digestions, and maintained in standard cell culture conditions. A cementocyte-like cell line was cloned (HCY-23, for human cementocyte clone 23), which presented a cementocyte compatible gene expression signature, including the expression of dentin matrix protein 1 ( DMP1 ), sclerostin ( SOST ), and E11/gp38/podoplanin ( E11 ). In contrast, these cells did not express the odontoblast/dentin marker dentin sialoprotein ( DSPP ). HCY-23 cells produced mineral-like nodules in vitro under differentiation conditions, and were highly responsive to inorganic phosphate (Pi). Within the limits of the present study, it can be concluded that cementocytes are phosphate-responsive cells, and have the potential do play a key role in periodontal homeostasis and regeneration.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Adulto Joven , Marcadores Genéticos/genética , Técnicas de Cultivo de Célula/métodos , Cemento Dental/citología , Fosfatos/farmacología , Fosfoproteínas/análisis , Fosfoproteínas/genética , Sialoglicoproteínas/análisis , Sialoglicoproteínas/genética , Factores de Tiempo , Glicoproteínas de Membrana/análisis , Glicoproteínas de Membrana/genética , Expresión Génica , Línea Celular , Análisis de Varianza , Proteínas de la Matriz Extracelular/análisis , Proteínas de la Matriz Extracelular/genética , Técnica del Anticuerpo Fluorescente , Proteínas Morfogenéticas Óseas/análisis , Proteínas Morfogenéticas Óseas/genética , Cemento Dental/metabolismo , Proteínas Adaptadoras Transductoras de Señales , Diente Molar/citología
11.
J Adhes Dent ; 20(4): 355-363, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30206578

RESUMEN

PURPOSE: To investigate the effect of polymerization stress and insertion technique on dentin micropermeability of composites placed under pulpal pressure. MATERIALS AND METHODS: One high-viscosity conventional (HC; Filtek Supreme Ultra; 3M Oral), one low-viscosity conventional (LC; Filtek Supreme Ultra Flowable; 3M Oral), one high-viscosity bulk fill (HBF; Filtek Bulk Fill Restorative; 3M Oral), and one low-viscosity bulk fill (LBF; Filtek Bulk Fill Flowable; 3M Oral) composite were evaluated. Polymerization stress was measured with materials bonded to acrylic rods in a universal testing machine (n = 5). Class I preparations were made in extracted molars, in which tooth roots were removed and the pulpal chambers cleaned. Preparations were coupled to a hydraulic device to simulate pulpal pressure during composite placement (n = 5). Conventional composites were placed in two horizontal increments, while bulk fill materials were placed in one, single increment. Fluid flow rate (µl/min) and dentin micropermeability (%) were monitored. The restoration interface was observed under confocal laser scanning microscopy. RESULTS: LC and LBF presented statistically significant higher polymerization stress than HC and HBF. Fluid flow rate and dentin micropermeability did not differ among the groups. However, different patterns of fluid infiltration and interface integrity were observed. HC and HBF presented well-sealed surrounding margins with small gaps along the pulpal wall, while HBF demonstrated more cracks in the adhesive layer. LC and LBF restorations had larger gaps along all bonded interfaces. CONCLUSION: No difference in polymerization stress was found when conventional and bulk fill composites with similar viscosities were compared. Neither polymerization stress or placement technique demonstrated a significant effect on dentin micropermeability. The incremental placement technique using a conventional, high-viscosity composite exhibited qualitatively better marginal integrity.


Asunto(s)
Cementos Dentales , Materiales Dentales , Resinas Compuestas , Restauración Dental Permanente , Análisis del Estrés Dental , Dentina , Ensayo de Materiales , Polimerizacion
12.
Braz. dent. j ; 29(1): 82-87, Jan.-Feb. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-888716

RESUMEN

Abstract The goal of this study was to evaluate in vitro the effect of the photoinitiator phenylpropanedione (PPD), alone or combined with camphorquinone (CQ), on color stability of photoactivated resin cements and their bond strength to ceramics using a micro-shear test. Four resin cements were used: a commercial brand cement (RelyX Veneer®) and 3 experimental cements with different types and concentration of photoinitiators. For color analysis, ceramic discs were cemented on bovine dentin specimens to simulate indirect restorations (n=8) and were exposed to UV for 120 h and tested for color alteration using a reflectance spectrophotometer and the CIEL*a*b* system. Data were analyzed by Anova and Tukey's test at 5% significance level. The color test results did not present statistically significant difference for the ∆E for all the studied cements, neither for ∆L, ∆a and ∆b. For the bond strength, all the studied cements showed statistically significant differences to each other, with the highest result for the RelyX Veneer® (29.07 MPa) cement, followed by the cement with CQ (21.74 MPa) and CQ+PPD (19.09 MPa) cement; the lowest result was obtained by the cement using only PPD as a photoinitiator (13.99 MPa). So, based on the studied parameters, PPD was not advantageous as photoinitiator of resin cements, because it showed a low value of bond strength to the ceramics and no superior color stability.


Resumo O objetivo deste estudo foi avaliar in vitro o efeito do fotoiniciador fenilpropanodiona (PPD), isoladamente ou em associação com a CQ, sobre a estabilidade de cor de cimentos resinosos fotoativados e sua resistência de união adesiva à cerâmica, por teste de microcisalhamento. Foram utilizados 4 cimentos resinosos, sendo um comercial (RelyX Veneer®) e 3 experimentais, diferindo entre si quanto ao tipo e concentração dos fotoiniciadores. Para a análise de cor foram cimentados discos cerâmicos sobre dentina bovina, simulando restaurações indiretas (n=8), sendo expostos a 120 h de UV e testados quanto às alterações de cor, que foram mensuradas empregando a escala CIEL*a*b*, por meio de espectrofotômetro de reflectância. Os dados obtidos foram verificados quanto à distribuição normal, submetidos a Anova e ao teste complementar Tukey, todos com significância de 5%. Os resultados do teste de cor não apresentam diferença estatisticamente significante para o ∆E dos 4 cimentos estudados, tampouco para ∆L, ∆a e ∆b. Para a resistência de união, todos os cimentos estudados apresentaram diferenças estatisticamente significantes entre si, com o maior resultado para o cimento comercial RelyX Veneer® (29,07 MPa), seguido pelo cimento com CQ (21,74 MPa), e cimento de CQ+PPD (19,09 MPa); o menor resultado foi obtido com o cimento utilizando apenas o PPD como fotoiniciador (13,99 MPa). Portanto, para os parâmetros estudados, o PDD não se mostrou vantajoso como fotoiniciador de cimentos resinosos, pois apresentou baixo valor de resistência de união à cerâmica e não demonstrou superioridade quanto à estabilidade de cor.


Asunto(s)
Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Luz , Cementos de Resina/química , Color , Ensayo de Materiales , Espectrofotometría/métodos
13.
Braz Dent J ; 29(1): 82-87, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29267530

RESUMEN

The goal of this study was to evaluate in vitro the effect of the photoinitiator phenylpropanedione (PPD), alone or combined with camphorquinone (CQ), on color stability of photoactivated resin cements and their bond strength to ceramics using a micro-shear test. Four resin cements were used: a commercial brand cement (RelyX Veneer®) and 3 experimental cements with different types and concentration of photoinitiators. For color analysis, ceramic discs were cemented on bovine dentin specimens to simulate indirect restorations (n=8) and were exposed to UV for 120 h and tested for color alteration using a reflectance spectrophotometer and the CIEL*a*b* system. Data were analyzed by Anova and Tukey's test at 5% significance level. The color test results did not present statistically significant difference for the ∆E for all the studied cements, neither for ∆L, ∆a and ∆b. For the bond strength, all the studied cements showed statistically significant differences to each other, with the highest result for the RelyX Veneer® (29.07 MPa) cement, followed by the cement with CQ (21.74 MPa) and CQ+PPD (19.09 MPa) cement; the lowest result was obtained by the cement using only PPD as a photoinitiator (13.99 MPa). So, based on the studied parameters, PPD was not advantageous as photoinitiator of resin cements, because it showed a low value of bond strength to the ceramics and no superior color stability.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Luz , Cementos de Resina/química , Animales , Bovinos , Color , Ensayo de Materiales , Espectrofotometría/métodos
14.
Braz Dent J ; 28(4): 474-481, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29160400

RESUMEN

The aim of this study was to evaluate microtensile bond strength (µTBS) of self-etch and etch-and-rinse adhesives systems compared in different dentin regions (central-CD or proximal-PD) in a class II cavity configuration. A class II (mesial-oclusal-distal) cavity configuration was simulated on 20 extracted human third-molars (4 mm wide/3 mm deep). Etch-and-rinse adhesive (Scotchbond Multi Purpose, n=5, SBMP and Optibond FL, n=5, OPFL) and self-etch adhesives (Clearfil SE Bond, n=5, CSE and Optibond XTR, n=5, OPXTR) were applied. Class II restorations were performed by incremental technique and photo-activated (Bluephase/G2). Samples were sectioned to beam shape (1 mm² cross-section), placed on Geraldeli's device for µTBS test (0.5 mm/min cross-head speed). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-resin, adhesive, mixed/resin or mixed/dentin. Samples (n=4) were prepared for scanning electron microscope observation. Data were submitted to one-way ANOVA with Split-Plot arrangement and Tukey's test (α=0.05). There were no statistically significant differences among SBMP, OPFL, CSE and OPXTR on CD (p>0.05). However, on PD for SBMP and OPFL, µTBS values were significantly lower compared to CSE and OPXTR (p<0.05). In all groups, mixed failure pattern was more frequently observed, except for SBMP/CD (adhesive). In class II type cavity configuration, PD location negatively influenced bond strength of etch-and-rinse adhesive systems. Opposite to self-etching adhesives, which presented higher bond strength values compared to etch-and-rinse adhesives in PD.


Asunto(s)
Recubrimientos Dentinarios , Dentina , Resistencia a la Tracción , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Diente Molar
15.
Biofouling ; 33(10): 807-818, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29022391

RESUMEN

This study evaluated the cytotoxicity and antimicrobial activity of analogs of cationic peptides against microorganisms associated with endodontic infections. L-929 fibroblasts were exposed to LL-37, KR-12-a5 and hBD-3-1CV and chlorhexidine (CHX, control), and cell metabolism was evaluated with MTT. The minimal inhibitory concentration (MIC) and the minimal bactericidal/fungicidal concentration (MBC/MFC) of the peptides and CHX were determined against oral pathogens associated with endodontic infections. Enterococcus faecalis and Streptococcus mutans biofilms were cultivated in bovine dentin blocks, exposed to different concentrations of the most efficient antimicrobial peptide and analyzed by confocal laser scanning microscopy. CHX and peptides affected the metabolism of L-929 at concentrations > 31.25 and 500 µg ml-1, respectively. Among the peptides, KR-12-a5 inhibited growth of both the microorganisms tested with the lowest MIC/MBC/MFC values. In addition, KR-12-a5 significantly reduced E. faecalis and S. mutans biofilms inside dentin tubules. In conclusion, KR-12-a5 is a non-cytotoxic agent with potent antimicrobial and anti-biofilm activity against oral pathogens associated with endodontic infections.


Asunto(s)
Antibacterianos/farmacología , Antiinfecciosos/farmacología , Péptidos Catiónicos Antimicrobianos/farmacología , Boca/microbiología , Péptidos Catiónicos Antimicrobianos/química , Biopelículas/efectos de los fármacos , Células Cultivadas , Clorhexidina/farmacología , Cromatografía Líquida de Alta Presión , Dicroismo Circular , Enterococcus faecalis/efectos de los fármacos , Humanos , Pruebas de Sensibilidad Microbiana , Streptococcus mutans/efectos de los fármacos , Catelicidinas
16.
Braz. dent. j ; 28(4): 474-481, July-Aug. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-888670

RESUMEN

Abstract The aim of this study was to evaluate microtensile bond strength (µTBS) of self-etch and etch-and-rinse adhesives systems compared in different dentin regions (central-CD or proximal-PD) in a class II cavity configuration. A class II (mesial-oclusal-distal) cavity configuration was simulated on 20 extracted human third-molars (4 mm wide/3 mm deep). Etch-and-rinse adhesive (Scotchbond Multi Purpose, n=5, SBMP and Optibond FL, n=5, OPFL) and self-etch adhesives (Clearfil SE Bond, n=5, CSE and Optibond XTR, n=5, OPXTR) were applied. Class II restorations were performed by incremental technique and photo-activated (Bluephase/G2). Samples were sectioned to beam shape (1 mm² cross-section), placed on Geraldeli's device for µTBS test (0.5 mm/min cross-head speed). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-resin, adhesive, mixed/resin or mixed/dentin. Samples (n=4) were prepared for scanning electron microscope observation. Data were submitted to one-way ANOVA with Split-Plot arrangement and Tukey's test (α=0.05). There were no statistically significant differences among SBMP, OPFL, CSE and OPXTR on CD (p>0.05). However, on PD for SBMP and OPFL, µTBS values were significantly lower compared to CSE and OPXTR (p<0.05). In all groups, mixed failure pattern was more frequently observed, except for SBMP/CD (adhesive). In class II type cavity configuration, PD location negatively influenced bond strength of etch-and-rinse adhesive systems. Opposite to self-etching adhesives, which presented higher bond strength values compared to etch-and-rinse adhesives in PD.


Resumo O objetivo deste estudo foi avaliar a resistência de união à microtração (µTBS) de sistemas adesivos auto-condicionantes e convencionais comparados por entre diferentes regiões dentinárias (central-DC ou proximal-DP) em um preparo cavitário classe II. Um preparo cavitário classe II (mesio-ocluso-distal) foi simulado em 20 terceiros molares humanos (4 mm largura/3 mm profundidade). Adesivos convencionais (Scotchbond Multi Purpose, n=5, SBMP e Optibond FL, n=5, OPFL) e adesivos auto-condicionantes (Clearfil SE Bond, n=5, CSE e Optibond XTR, n=5, OPXTR foram aplicados. As restaurações classe II foram realizadas usando a técnica incremental e fotoativadas (Bluephase/G2). As amostras foram seccionadas em forma de palito (1 mm2 secção transversal), posicionadas no dispositivo de Geraldeli para o teste µTBS (velocidade transversal de 0,5 mm/min). O padrão de fratura foi analisado em estereoscópio e classificado em coesivo-resina, adesivo, misto/resina, misto/dentina. Amostras (n=4) foram preparadas para observação em microscópio eletrônico de varredura. Os dados foram submetidos a ANOVA um fator e teste de Turkey (α=0,05). Não houve diferença estatística significante entre SBMP, OPFL, CSE, e OPXTR em DC (p>0,05). Entretanto, para SBMP e OPFL em DP, valores µTBS foram significativamente menores comparados com CSE e OPXTR (p<0,05). Em todos os grupos, o padrão de fratura misto foi o mais frequentemente observado, exceto em SBMP/CD (adesivo). Em um preparo classe II, a localização da DP influenciou negativamente a resistência de união de sistemas adesivos convencionais. Oposto aos adesivos auto-condicionantes, que em DP apresentaram valores de resistência de união maiores comparados com adesivos convencionais.


Asunto(s)
Humanos , Resistencia a la Tracción , Recubrimientos Dentinarios , Dentina , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Diente Molar
17.
Biofouling ; 32(9): 995-1006, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27538256

RESUMEN

This study evaluated the cytotoxicity and effect of fragments derived from three oral cationic peptides (CP): LL-37, D6-17 and D1-23 against cariogenic bacteria under planktonic and biofilm conditions. For cytotoxicity analysis, two epithelial cell lines were used. The minimum inhibitory concentration and the minimal bactericidal concentration were determined for the CP fragments and the control (chlorhexidine-CHX) against cariogenic bacteria. The fractional inhibitory concentration was obtained for the combinations of CP fragments on Streptococcus mutans. Biofilm assays were conducted with the best antimicrobial CP fragment against S. mutans. The results indicated that D6-17 was not cytotoxic. D1-23, LL-37 and CHX were not cytotoxic in low concentrations. D1-23 presented the best bactericidal activity against S. mutans, S. mitis and S. salivarius. Combinations of CP fragments did not show a synergic effect. D1-23 presented a higher activity against S. mutans biofilm than CHX. It was concluded that D1-23 showed a substantial effect against cariogenic bacteria and low cytotoxicity.


Asunto(s)
Antibacterianos/farmacología , Péptidos Catiónicos Antimicrobianos/farmacología , Biopelículas/efectos de los fármacos , Fragmentos de Péptidos/farmacología , Plancton/efectos de los fármacos , Streptococcus mutans/efectos de los fármacos , Antibacterianos/toxicidad , Péptidos Catiónicos Antimicrobianos/toxicidad , Línea Celular , Supervivencia Celular/efectos de los fármacos , Clorhexidina/farmacología , Clorhexidina/toxicidad , Caries Dental/microbiología , Humanos , Pruebas de Sensibilidad Microbiana , Fragmentos de Péptidos/toxicidad , Streptococcus mutans/crecimiento & desarrollo , Streptococcus mutans/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...